Media Kit
For advertisements and demographics
click here
On Line Reader Service
 Publisher's Letter
What a Year!

 Assembly Lines
Art for Art's Sake - Or What Is Intel's Dr. Noyce Doing on an AMD Sculpture?

 Standards
New Lead-Free Finishes Require Testing to Determine Best Reflow Temperatures

 Wafer-Level Watch
Wafer Level Establishes a Beachhead

 Harvey Miller's Notebook
Cost of Leadframe Packages Falling, Raising Cost of Entry for WLCSPs

 Industry News
Company News
People in the News
Packaging Foundries
Letters
Calendar of Events
Editorial Index

 Features
Cover Story: X-Ray Inspection - Increasingly Popular, Systems Offer a Non-Destructive View
Directory of X-Ray Inspection System Suppliers

Cover Story: How Ultrasound 'Sees' CSP Defects

Cover Story: Socket Makers Face New Demands for Tighter Pitches and More I/0s

Directory of Socket Vendors

A Critcal Review of the Top CSP Patents

Keep the Reliability, Dump the Lead: Japanese Companies Accelerate Lead-Free Packaging

 Technical Forum
Wire Bonding Optoelectronics Packages

 Tools & Technologies
Thermagon Claims 'Lowest' Impedance for Conductive Film and more...

 Archives
2001
Jan-Feb March April
May-June July Aug-Sep
October Nov-Dec  
2000
Jan-Feb Mar-Apr May-June
July-Aug Sept-Oct Nov-Dec
1999
Jan-Feb Mar-Apr May-June
July-Aug Sept-Oct Nov-Dec
1998
  Mar-Apr May-June
July-Aug Sept-Oct Nov-Dec


Subscription

 
Current Issue
The International Reference for Chip-Scale Electronics, Flip-Chip Technology, Optoelectronic Interconnection and Wafer-Level Packaging
November - December 2001

How Ultrasound 'Sees' CSP Defects

By Steve Martell, Sonoscan Inc., Elk Grove Village, Illinois

When employing sonography, remember that image resolution is not always synonymous with the frequency of the ultrasound pulsed by a given transducer.

Because CSPs pack great power into very small areas, the hidden internal defects that wreak havoc with CSPs are likewise very small.

Accurately imaging and correctly diagnosing internal defects require the very high resolution of acoustic micro-imaging.

Image resolution is usually thought to be synonymous with the frequency of the ultrasound pulsed by a given transducer. The higher the frequency, the greater the spatial resolution. In some limited cases, this statement is basically true.

Very high resolution image gated at the second layer of metallization in a CSP. Irregular dark areas are voids in the elastomer layer.

Usually, however, there are other critical factors whose overall impact is such that a transducer with a higher frequency may offer less spatial resolution than a transducer of lower frequency.

The design of the transducer lens, the frequency spectrum of the pulser and the thickness of the sample (especially at very high frequencies) matter greatly.

Different transducers with the same nominal frequency can be designed to do different jobs. Therefore, you may find a group or family of transducers with the same or similar nominal frequencies, which are designed for different purposes.

Optimum results in imaging a given sample take place when the right transducer is used on the sample.

The number of data points collected during scanning also affects resolution in the acoustic image.

For years the standard was 512 x 480 pixels. Where truly superb resolution is needed-as in CSPs-the new high-end image size of approximately 8,000 x 8,000 pixels is a good choice. [sonoscan.com]

 