| Changes to JEDEC's Moisture
Sensitivity Classification for SMDs Likely Soon |
|
How
to classify and handle moisture sensitive surface mount devices
is a daily discussion topic in every semiconductor company
and OEM in the world. The more moisture sensitive the SMD
is, the more costly it is to handle.
|
 |
|
By
Mark Bird Contributing Editor
|
Moisture
Sensitivity
The USA Moisture Sensitivity Classification
(J-STD-020A) and Handling (J-STD-033) standards are the two specifications
that have the greatest impact on SMDs. These standards are maintained
under the joint standards efforts of the IPC and JEDEC. The April
1999 revisions of these standards can be found at the JEDEC web
site www.jedec.org.
The present moisture sensitivity standard contains
the seven levels shown in the table. The purpose of this standard
is to identify the moisture sensitivity level at a fixed reflow
temperature, so that the user can properly store and handle the
SMDs to avoid subsequent thermal/mechanical damage during the assembly
reflow attachment and /or repair operations.
|
Jedec
Moisture Sensitivity Classification
|
|
LEVEL
|
FLOOR
LIFE
|
SOAK REQUIREMENTS
|
|
Standard
|
Accelerated
Equivalent
|
|
TIME
|
CONDITIONS
|
TIME
(Hours)
|
CONDITIONS
|
TIME
(Hours)
|
CONDITIONS
|
|
1
|
Unlimited
|
<30oC/85%/RH
|
168
|
85oC/85%/RH
|
|
|
|
2
|
One
Year
|
<30oC/60%/RH
|
168
|
85oC/60%/RH
|
|
|
|
2a
|
Four
Weeks
|
<30oC/60%/RH
|
6962
|
30oC/60%/RH
|
120
|
60oC/60%/RH
|
|
3
|
168
Hours
|
<30oC/60%/RH
|
1922
|
30oC/60%/RH
|
40
|
60oC/60%/RH
|
|
4
|
72
Hours
|
<30oC/60%/RH
|
962
|
30oC/60%/RH
|
20
|
60oC/60%/RH
|
|
5
|
48
Hours
|
<30oC/60%/RH
|
722
|
30oC/60%/RH
|
15
|
60oC/60%/RH
|
|
5a
|
24
Hours
|
<30oC/60%/RH
|
482
|
30oC/60%/RH
|
10
|
60oC/60%/RH
|
The lower the level, the longer an SMD's floor life.
The goal of all package manufacturers is to have their packages
reach Level 1, which would be an unlimited floor life.
Reflow
Temperatures
The present moisture sensitivity classification
uses two reflow temperatures, 220oC and 235oC
to classify packages. The packages are classified generally to the
lowest level for moisture sensitivity, and to the highest reflow
temperatures possible, to give the OEMs the largest process window
when mounting the packages to boards.
The second standard's purpose is to provide
SMD manufacturers and users with methods for handling SMDs. These
methods are provided to avoid damage from moisture absorption and
exposure to reflow temperatures that may result in yield and reliability
degradation.
These two standards are very important and are
widely used in the industry. It is already time to revise both documents.
The Joint Task Group of IPC and JEDEC has began revision activities
in Tempe, Ariz., in February.
The major factor driving the changes stems from
the requirement for moisture sensitivity classification to add a
third reflow classification temperature of 260oC. This
new, higher temperature is being added to accommodate the higher
temperature profiles needed for some lead-free mounting applications.
This higher temperature requirement will definitely
make the classification of current packages a real challenge at
any classification level.
Many of the present SMD packages may drop two,
three or more levels when subjected to the higher 260oC
temperature. It is important to provide as much industry support
as possible to the JEDEC and IPC task groups to ensure a useful
and productive specification revision is created.
Contact your representative if you can add value
to this critical update. The Joint Task Group is targeting late
2000 or early 2001 for publishing the next revisions of the standards,
therefore little time remains.
|
Mr. Bird is an Amkor Technology Fellow
and the director of technical marketing at Amkor in Chandler,
Ariz. Readers may contact him at mbird@amkor.com
or by phone at 480.821.5000.
|
|